<LOGO>
FM Transmitter Measurement Report
Created: 2026-03-02 05-07-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.30 MHz 5/5, 84 dBuV 00s&10s
Pilot RDS Phase Difference
6.2 kHz 3.9 kHz -89 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 69 kHz 19147 8,6437
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,9 dBr 5,10 dBr 5,8 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"00s&10s " 249E 10 (Pop M) 1 0 1 1 5:05, 2.03.2026
RT
"MPB Radi "
AF EON
95.6, 96.3, 96.6, 96.9, 97.3, 97.7, 105.5 MHz 6053, 4F14, 43B3, F84A
FM Scope Max at: 69 kHz MIN: 11 kHz % above 76 kHz: 8,6437 Acquired: 2026/03/02 5.06.06 Total samples: 19147 Equivalent time: 0:15:57 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,8 dBr MIN: 3,9 dBr AVE: 5,10 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2026/03/02 5.06.05) 04.52 04.54 04.56 04.58 05.00 05.02 05.04 05.06 0 2 4 6 Pm [dBr]